|
Sign In to gain access to subscriptions and/or personal tools.
|
Estimating Milk Intake of Hospitalized Preterm Infants Who Breastfeed
Paula P. Meier, DNSc, FAAN
Janet L. Engstrom, PhD, CNM
Barbara A. Fleming, RNC, MS
Pamela L. Streeter, RN, MS
Patricia B. Lawrence, MSN, CLE
This study describes the accuracy of clinical indices to estimate the milk intake of breastfed preterm infants. Twenty-nine mother-infant pairs were studied for a total of 39 breastfeeding sessions. Two NICU nurses (RN1 and RN2) and one certified lactation educator (CLE) collected data, each blind to the others' measures. RN1 and RN2 performed test-weights using the Smart Model 20 electronic scale. The CLE observed the breastfeeding and estimated milk intake, using clinical indices of milk transfer. Clinical indices did not provide an accurate estimate of milk intake (r=.48). The mean absolute difference between the test-weights and clinical estimates was 5.79 ml, with a maximal difference of 20 ml. These differences were random in that clinical indices did not consistently over- or underestimate milk intake. None of 17 clinical indices of milk intake significantly lowered the magnitude of error in the clinical esti mate. These data suggest that clinical indices cannot serve as a replacement for test- weighing of preterm infants when an accurate estimate of milk intake is necessary. JHL 12:21-26, 1996.
Key Words: breastfeeding milk intake preterm infants test-weighing
Journal of Human Lactation, Vol. 12, No. 1,
21-26 (1996)
DOI: 10.1177/089033449601200106

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
A. K. Spangler, A. L. Randenberg, M. G. Brenner, and M. Howett
Belly Models as Teaching Tools: What Is Their Utility?
J Hum Lact,
May 1, 2008;
24(2):
199 - 205.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
O E M Savenije and P L P Brand
Accuracy and precision of test weighing to assess milk intake in newborn infants
Arch. Dis. Child. Fetal Neonatal Ed.,
September 1, 2006;
91(5):
F330 - F332.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
L. Furman and N. M. Minich
Evaluation of Breastfeeding of Very Low Birth Weight Infants: Can We Use the Infant Breastfeeding Assessment Tool?
J Hum Lact,
May 1, 2006;
22(2):
175 - 181.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
P. D. Hill, J. C. Aldag, R. T. Chatterton, and M. Zinaman
Comparison of Milk Output Between Mothers of Preterm and Term Infants: The First 6 Weeks After Birth
J Hum Lact,
February 1, 2005;
21(1):
22 - 30.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
N. M. Hurst, P. P. Meier, J. L. Engstrom, and A. Myatt
Mothers Performing In-Home Measurement of Milk Intake During Breastfeeding of their Preterm Infants: Maternal Reactions and Feeding Outcomes
J Hum Lact,
May 1, 2004;
20(2):
178 - 187.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
L. G. Leonard
Breastfeeding Higher Order Multiples: Enhancing Support During the Postpartum Hospitalization Period
J Hum Lact,
November 1, 2002;
18(4):
386 - 392.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
P. P. Meier, L. P. Brown, N. M. Hurst, D. L. Spatz, J. L. Engstrom, L. C. Borucki, and A. M. Krouse
Nipple Shields for Preterm Infants: Effect on Milk Transfer and Duration of Breastfeeding
J Hum Lact,
May 1, 2000;
16(2):
106 - 114.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
L. J. Smith
When to Supplement a Supposedly Breastfed Baby
J Hum Lact,
June 1, 1998;
14(2):
145 - 146.
[PDF]
|
 |
|
|
|